Research Article| Volume 116, ISSUE 1, P22-27, September 10, 2004

The quality of intrapartum fetal heart rate monitoring

      Abstract

      Objective: To determine the quality of fetal heart rate (FHR) recordings during the first and second stage of labor by quantifying the amount of fetal signal loss in relation to the method of monitoring: external ultrasound or directly via a scalp electrode. Study Design: Analysis of 239 intrapartum recordings stored between 1 January 2001 and 1 July 2001 from consecutive deliveries at the Vrije Universiteit Medical Center in Amsterdam. Singletons delivered via the vaginal route were included in the study. FHR recordings had duration of at least 1 h prior to birth of the infant. Subdivision in three groups took place on the basis of the recording technique which had been used; i.e. ultrasound, scalp electrode or a combination of both methods. FHR data was obtained using HP-M1350 cardiotocographs. The status (pen on, pen off, maternal signal) and the mode of the signals were acquired. The duration of pen lifts and maternal signals was divided by the total duration of the recording. Statistical analyses were performed with the Mann–Whitney U-test and the Wilcoxon signed ranks test. Results: Recordings obtained via ultrasound demonstrated significantly more fetal signal loss than those obtained via the direct mode, particularly in the second stage. The FIGO criteria for fetal signal loss with external ultrasound were not fulfilled during this stage for about half the cases. Conclusion: Intrapartum FHR monitoring via a scalp electrode provides far better quality FHR signals than external ultrasound and deserves a more prominent position in fetal surveillance than it currently has.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      References

        • Shewa A
        • Hacker T.W
        • Nuovo J
        Interpretation of the electronic fetal heart rate during labour.
        Am. Family Phys. 1999; 59: 2507-2512
        • Amer-Wåhlin I
        • Hellsten C
        • Norén H
        • et al.
        Cardiotocography only versus cardiotocography plus ST analysis of fetal electrocardiogram for intrapartum fetal monitoring: a Swedish randomised controlled trial.
        Lancet. 2001; 358: 534-538
        • Strachan K.B
        • Sahota D.S
        • van Wijngaarden W.J
        • James D.K
        • Chang A.M.Z
        Computerised analysis of the fetal heart rate and relation to academia at delivery.
        Br. J. Obstet. Gynaecol. 2001; 108: 848-852
        • Strachan B.K
        • van Wijngaarden W.J
        • Sahota D
        • Chang A
        • James D.K
        Cardiotocography only versus cardiotocography plus PR-interval analysis in intrapartum surveillance: a randomised, multicentre trial.
        Lancet. 2000; 355: 456-459
      1. Kripke CC. Why are we using electronic fetal monitoring? Am Family Phys 1999;59(9):2416, 21–2 [Editorial].

        • Parer J.T
        • King T
        Fetal heart rate monitoring: is it salvageable?.
        Am. J. Obstet. Gynecol. 2000; 182: 982-987
        • Spencer J.A.D
        • Belcher R
        • Dawes G.S
        The influence of signal loss on the comparison between computer analyses of the fetal heart rate in labour using pulsed Doppler ultrasound (with autocorrelation) and simultaneous scalp electrocardiogram.
        Eur. J. Obstet. Gynecol. Reprod. Biol. 1987; 25: 29-34
        • Dawes G.S
        Numerical analysis of the human fetal heart rate: the quality of ultrasound records.
        Am. J. Obstet. Gynecol. 1981; 141: 43-52
        • Rooth G
        • Huch A
        • Huch R
        Guidelines for the use of fetal monitoring.
        Int. J. Gynecol. Obstet. 1987; 25: 159-167
      2. Clinical Effectiveness Support Unit. The use of electronic fetal monitoring. The use of cardiotocography in intrapartum fetal surveillance. Evidence-based clinical guideline number 8. London: RCOG Press, 2001.

      3. Ingemarsson I, Ingemarsson E, Spencer JAD. Technical aspects of fetal heart rate monitoring. In: Fetal heart rate monitoring a practical guide. Oxford: Oxford University Press, 1993. p. 12–26.

      4. Freeman RK, Garite JT, editors. Instrumentation, artefact detection, and fetal arrhythmias. In: Fetal heart rate monitoring. Baltimore: Williams & Wilkins, 1981. p. 28–54.

        • Van Geijn H.P
        • Jongsma H.W
        • de Haan J
        • Eskes T.K
        Analysis of heart rate and beat-to-beat variability: interval difference index.
        Am. J. Obstet. Gynecol. 1980; 138: 246-252
        • Solum T
        A comparison of the three methods for external fetal cardiography.
        Acta Obstet. Gynecol. Scand. 1980; 59: 123-126
      5. Gibb D, Arulkumaran S, editors. Introduction. In: Fetal monitoring in practice. Oxford: Butterworths/Heinemann, 1992. p. 1–7.

      6. Neilson JP. Fetal electrocardiogram (ECG) for fetal monitoring during labour (Cochrane methodology review). Cochrane Library, No. 4, 2003.

        • Zuspan F.P
        • Quilligan E.J
        • Iams J.D
        • Van Geijn H.P
        Predictors of intrapartum fetal distress: the role of electronic fetal monitoring. Report of the National Institute of Child Health and Human Development. Consensus Development Task Force.
        Am. J. Obstet. Gynecol. 1979; 135: 287-291